Browsed by
Tag: viscosity controller

Fuel Oil Viscosity Controller Working Principle

Fuel Oil Viscosity Controller Working Principle

Basic Principle of Viscosity Controller

The basic principle of the Viscotherm viscosity monitoring device or viscosity controller is shown in the figure below. A continuous sample of the fuel is pumped at a constant rate through a fine capillary tube. As the flow through the tube is laminar, pressure drop across the tube is proportional to viscosity.

viscosity controller
Viscosity Controller

In this viscosity controller unit an electric motor drives the gear pump through a reduction gear at a speed of 40 rpm. The pump is positioned in the chamber through which fuel is passing from the heater to the fuel pumps or combustion equipment. Tapping points are provided to enable the pressure difference to be measured by means of a differential pressure gauge. The gauge is calibrated directly in terms of viscosity. Parts in contact with the fuel are of stainless steel for corrosive resistance.

A differential pressure transmitter shown below provides an analogue of viscosity to a pneumatic controller, which regulates the supply of fuel heating steam through a control valve.

differential_pressure_transmitter

 

References

“REED’S GENERAL ENGINEERING KNOWLEDGE FOR MARINE ENGINEERS”, by Leslie Jackson and Thomas D. Morton

    HP P