Breathing Apparatus Entry Log
This log must be maintained at all times when CABA’s are in use.
SET NO. | WEARER NAME | PRESSURE | TIME ON | DUE OUT | TIME OUT | REMARKS |
A 1200 litre bottle fully charged to 200 bar would last approximately 20 minutes.
This can be significantly reduced in an Emergency situation when the wearer is under stress and making a lot of effort.
Larger or unfit persons will also consume more air.
The following gives a guide to the working duration that can be expected under normal conditions and can be used to assist in calculating the DUE OUT time (5th column).
PRESSURE | DURATION | The table on the left is based on a standard
1200 litre bottle charged to 200 bar. |
PRESSURE | DURATION |
200 Bar | 20 Minutes | |||
180 Bar | 17 Minutes | The calculation is based on average air consumption of 40 litres per minute. The | ||
160 Bar | 14 Minutes | Working duration allows for a safety reserve of 10 minutes. | ||
140 Bar | 11 Minutes | |||
120 Bar | 8 Minutes | If your bottle sizes are not 1200 litre you should calculate the expected duration times per the Safety Manual and enter | ||
100 Bar | 5 Minutes | them in the blank box provided. | ||
67 Bar | 0 Minutes | |||
<67 Bar | GET OUT |