Breathing Apparatus Entry Log

Breathing Apparatus Entry Log

This log must be maintained at all times when CABA’s are in use.

 

SET NO. WEARER NAME PRESSURE TIME ON DUE OUT TIME OUT REMARKS
             
             
             
             
             
             
             

 

A 1200 litre bottle fully charged to 200 bar would last approximately 20 minutes.

This can be significantly reduced in an Emergency situation when the wearer is under stress and making a lot of effort.

Larger or unfit persons will also consume more air.

The following gives a guide to the working duration that can be expected under normal conditions and can be used to assist in calculating the DUE OUT time (5th column).

 

PRESSURE DURATION The table on the left is based on a standard

1200 litre bottle charged to 200 bar.

PRESSURE DURATION
200 Bar 20 Minutes      
180 Bar 17 Minutes The calculation is based on average air consumption of 40 litres per minute.  The    
160 Bar 14 Minutes Working duration allows for a safety reserve of 10 minutes.    
140 Bar 11 Minutes      
120 Bar 8 Minutes If your bottle sizes are not 1200 litre you should calculate the expected duration times per the Safety Manual and enter    
100 Bar 5 Minutes them in the blank box provided.    
67 Bar 0 Minutes      
<67 Bar GET OUT      

 

Leave a Reply

Your email address will not be published. Required fields are marked *

    HP P