Daily Archives: September 13, 2014

You are browsing the site archives by date.

Dual Fuel Marine Engines used on-board Ships

Dual fuel engines can be operated on natural gas as well as fuel oil. Change over from one fuel to the other can be achieved without any interruption in the power output of the engine. This article explains some important features of dual fuel engine used in gas carriers.

lng carrier ship

Methods of Introduction of Natural Gas into the Engine

  1. Admit low pressure gas through gas admission valve when exhaust valve is closed and when pressure in the cylinder is low. Gas is compressed along with the air and the mixture is ignited by a pilot injector which inject small amount of fuel oil to the combustion space or using spark plugs (for small engines). In the case of pilot injector, the injection of fuel oil into the combustion space result in ignition of fuel and thereby gas. The disadvantage of this method is that it produces knocking and comparatively less efficient.
  2. Natural gas is compressed to around 250-300 bar, injected to the combustion space at the same time as that of pilot fuel injector. this method is found to be more efficient.

Working Modes of Dual Fuel Engines

There are basically 3 modes of operation for dual fuel marine engines used on-board ships.

  1. When engine is well supplied with natural gas, amount of pilot fuel injected is corresponding to 6% of the total engine load. In other words major contributor to the engine load is natural gas.
  2. When gas supply to the engine is constant and limited, then engine is said to be in “Specified Gas Mode”. Here gas supply is constant, but fuel oil quantity injected varies to meet changing engine load demand.
  3. In “Fuel Oil Only” mode, gas supply will not be available, and engine runs only on fuel oil. This mode is used when engine is unstable, such as during restricted waters, heavy weather, manoeuvring, etc.

duel fuel marine diesel engine Features of Dual Fuel Engines

  • Natural gas is compressed to about 250-300 bar using a number of compressors, working in series. Compressed gas is then cooled and led to valve blocks of each cylinder unit.
  • Each valve block is fitted with an accumulator (it has a capacity to store about 20 times of the amount of gas injected to the unit at full load) for minimizing pressure drop during injection and to monitor pressure drop in case of any abnormality in the system (such as gas injection valve stuck open).
  • The gas supply pipe lines are double walled. Compressed air is passed between the two walls (air seal), which is continuously monitored for any gas detection (gas is detected means leakage of gas).
  • Outer wall of the gas pipe is made of stainless steel to withstand very low temperatures, in case of a leakage from inner pipe.
  • Whenever the flow of compressed air between the gas supply pipe walls fail, the gas supply shut down and the line is purged with inert gas.
  • For lubrication of parts and sealing of gas, gas injectors are supplied with sealing oil. (Sealing oil is pressurized to about 25-30 bar above gas injection pressure, and the sealing oil is injected and burnt along with the gas).
  • Consumption of the sealing oil is very low, in the order of 0.13 g/kWh.
  • The sealing oil system consist of two pumps for redundancy and a spring loaded accumulator to maintain the sealing oil pressure, since standby pump takes time to build up pressure when one pump fails.
  • When a gas injection valve is stuck open (jammed), then gas pressure drops at the accumulator in the valve block, resulting in gas system shut down and pipe lines are purged with inert gas.
  • If the pressure drop is not detected in the above case, then more gas burn, exhaust temperature rises. This results in gas supply shut down.
  • In the case of late ignition while burning gas, there will be rapid pressure rise in the exhaust system. hence exhaust gas receiver is designed to withstand 15 bar pressure.
  • Failure of pilot fuel oil system result in combustion failure of gas, then gas supply shut down and lines are purged with inert gas.

IACS (International Association of Classification Societies) Require Following Safeties in Dual Fuel Engines

  • Use oil fuel only while starting the engine.
  • Use oil fuel only during unstable engine conditions, such as manoeuvring, restricted waters, etc.
  • Engine should continue to run on fuel oil even when gas supply stops.
  • Crankcase relief valves to be fitted in way of each crank throw.
  • Construction and operation of pressure relief valve of engine units should consider gas leak inside the engine and subsequent pressure rise.
  • Exhaust gas system of the engine to be independent and not to be mixed with any other systems.
  • Starting air line to each unit to be fitted with flame arresters.
  • Flame arrester to be fitted at the inlet of the gas supply valve to the units.
  • Apart from automatic shut down system, gas supply must be able to shut manually from engine starting platform or other control stations.

 

    HP P